Pediatr. praxi. 2010;11(1):52-53

Safe nursing practices - evaluation of correct placement of a gastric tube in neonates and infants

Mgr.Jaroslava Fendrychová, Ph.D.
Katedra ARIPP, NCO NZO Brno

Assessing whether gastric feeding tube have been correctly placed is an important and difficult proces. Many different methods have been

recomended, but nurses are not sure which of them is the most accurate. There is no relevant studies in Czech databases, so I have used

the recommendation of the UK National Patient Safety Agency (NPSA) from the August 2005 and Pennsylvania Patient Safety Authority

(2006) and I offer it to nurses for the practical use.

Keywords: gastric tube, correct placement, methods of control

Published: March 1, 2010  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Fendrychová J. Safe nursing practices - evaluation of correct placement of a gastric tube in neonates and infants. Pediatr. praxi. 2010;11(1):52-53.
Download citation

References

  1. Tománková L. Péče o novorozence na vlnách času aneb pohled do historie neonatologie. Čes.-slov. Pediatrie 2006; 61(2): 76-83.
  2. Durai R, et al. Nasogastric tubes 1: insertion technique and confirming position. Nursing Times, 2009.
  3. Gordon S. Newborns in Intensive Care Often Exposed to Pain. [online]. [citováno 2009-07-31] dostupné z http://health.usnews.com/articles/health/healthday.
  4. Kapounová G. Ošetřovatelství v intenzivní péči. Praha: Grada Publishing, 2007: 350.
  5. Fendrychová J, Borek I, a kol. Intenzivní péče o novorozence. Brno: NCO NZO, 2007: 403.
  6. Mikšová Z, Froňková M, Hernová R, Zajíčková M. Kapitoly z ošetřovatelské péče I. Aktualizované a doplněné vydání. Praha: Grada Publishing 2006: 248.
  7. Tyburec J, a kol. Enterální výživa sondou u Crohnovy choroby. [online] [citováno 2009-07-17] dostupné na: http://www.crohn.cz/colitiscrohn/print.asp?productid=299&detailSubCatCode=124.
  8. Krišková A, a kol. Ošetrovateľské techniky. Martin: Osveta, 2001: 804.
  9. PA-PSRS (Pennsylvania Patient Safety Reporting System) Confirming Feeding Tube Placement: Old Habits Die Hard. 2006; 3(4): 1-10.
  10. Fendrychová J, Klimovič M, a kol. Péče o kriticky nemocné dítě. Brno: NCO NZO, 2005: 414.
  11. Orkman BA, Bennett CL. Klíčové dovednosti sester. Praha: Grada Publishing 2006: 259.
  12. Hockenberry MJ. Wong´s clinical manual of pediatric nursing. St. Louis: Mosby, 2004: 759.
  13. National patient safety agency (NPSA), 2005. Patient safety alert 09. Reducing the harm caused by misplaced naso and orogastric feeding tubes in babies under the care of neonatal units. [online] [citováno 2009-07-27] dostupné na: www.npsa.nhs.uk/advice.
  14. Zeleníková R, Mandysová P. Kontrola umístění nazogastrické sondy před zahájením enterální výživy u dospělých pacientů. Profese on-line, 2008; 1/2 : 113-122. Go to original source...
  15. Metheny NA, Aud MA. Detection of improperly positioned feeding tubes. Journal of Health Risk Manag. 1993; 22(3): 224-225.
  16. Hair J. Guidelines for testing the placing of nasogastric tubes. Nursing Times 2005; 101(20): 26.
  17. Metheny NA, Meert KL. Monitoring Feeding Tube Placement. Nutrition in Clinical Practice, 2004; 19(5): 487-495. Go to original source... Go to PubMed...




Pediatrics for Practice

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.